  • HOARDING BOARD ASSESSMENT AT AIRPORT

    Condition Assessment Using Non Destructive Technique SR. No. Location of Plant/ Name of Test Rebound Hammer         IS 13311 (Part-2)-1992 USPV   IS 13311 (Part-1)-1992 Dye Penetration Test  ASTM-E165 Limit value/Parameters as per given Standards/codes Average rebound number Quality of concreteAbove 40 Very good layer,Between 30 and 40 Good layer, Between 20 to 30 Fair,Less than 20…

  • STRUCTURE HEALTH ASSESSMENT OF EXISTING SCHOOL BUILDING AT KOLKATA, WEST BENGAL

    Executive Summary: Based on the Visual Inspection & NDT Results  Of all the Structural Members of the Existing Building In order to assess the structural stability of the building, following tests were conducted at site Rebound Hammer Test as per IS: 13311 (Part-2)-1992 for determining the estimated compressive strength and uniformity of concrete in terms…

  • STRUCTURE DESIGN REPORT FOR VETTING

    PROJECT 8.46 m x 16.46 M COWS SHED (Conventional truss) AT NEAR ELECTRICAL SUB – STATION KHASRA NO – 130 / 3 STRUCTURAL CONSULTANTS O.B Developers (STRUCTURE AUDIT AGENCY) F 14, Kalkaji main road, new delhi-110019 mOB: +91-9717924616 Email; structureauditagency@gmail.com WWW.STRUCTUREAUDITAGENCY.COM INTRODUCTION The structure is a RCC + Steel(Truss) Framed Structure located at NEAR ELECTRICAL…

  • COMPOSITE SLAB DEFLECTION TESTING REPORT

    Prepared By:- O.B DEVELOPERS (STRUCTURE AUDIT AGENCY) F 14, Kalkaji Main Road , New Delhi-110019 Email- strutureauditagency@gmail.com Call-+91-9717924616 1.  INTRODUCTION Deflection testing adopted as per M/s O.B Developers.  and it is used only to evaluate whether a structure or a portion of a structure satisfies the  deflection safety requirements 2.  SCOPE To evaluate whether a…

  • SLAB DEFLECTION OF 10 METER UNSUPPORTED CONTROL MEASUREMENT AND RETROFITTING

    Prepared By:- O.B DEVELOPERS (STRUCTURE AUDIT AGENCY) F 14, Kalkaji Main Road , New Delhi-110019 Email- strutureauditagency@gmail.com Call-+91-9717924616 www.structureauditagency.com Executive Summary: Based on the Visual Inspection & NDT Results  Of all the Structural Members of the Existing Building In order to assess the structural stability of the building, following tests were conducted at site Rebound…

  • COAL PIT EXTRACTION PIT FRAME AUDIT

    STRUCTURAL AUDIT REPORT REPORT NAME  : STRUCTURE STABILITY ANALYSIS PROJECT LOCATION : Pit A, B & C STRUCTURAL CONSULTANTS O.B Developers (STRUCTURE AUDIT AGENCY) F-14, Kalkaji main road new delhi-110019 MOB: +91-9717924616 structureauditagency@gmail.com WWW.STRUCTUREAUDITAGENCY.COM INTRODUCTION The structure is a Steel Stack Industrial Structure located at xxxxxx. In this report the design datasheet is attached along with various…

  • WIRE ROPE ANALYSIS OF EXISTING CHANDELIERS IN BANQUETS AT DELHI

    Executive Summary: Based on the Visual Inspection & NDT Results Of all the Wire of the Existing structure In order to assess the structural stability of the building, following tests were conducted at site Wire Thickness Reduction Test : This Test is performed to check the reduction in the wire diameter due to rusting Estimated…

  • SITE INSPECTION AND CONCEPTUAL DESIGN METHODOLOGY OF RETROFITTING/STRENGTHEN FOR THE COLUMNS DAMAGED

    OF xxxxx ALLAHABAD BANK, xxxxx, FARIDABAD, HARYANA Prepared By:- Structural Audit Agency O.B. Developers 610,  SECTOR 87, FARIDABAD HARYANA-121002 PHONE NO:- +919717924616 www.structureauditagency.com structureauditagency@gmail.com Report Summary The Apartment is located at xxxx, Faridabad, Haryana The house is under construction work and currently the r work is under process. Site visit was carried out on 20/08/2020(4.00…

  • STRUCTURE AUDIT OF A CNG PUMP STEEL CANOPY

    STRUCTURAL AUDIT REPORT PROJECT NAME                        : ANALYSIS  of EXISTING CNG PUMP  CANOPY                          PROJECT LOCATION              : SONIPAT, HARYANA STRUCTURAL CONSULTANTS O.B Developers (STRUCTURE AUDIT AGENCY) F-14, Kalkaji main road new delhi-110019 MOB: +91-9717924616 structureauditagency@gmail.com WWW.STRUCTUREAUDITAGENCY.COM INTRODUCTION The structure is a CNG FILLING STATION CANOPY located at SONIPAT, HARYANA. In this report the design data sheet…

  • CONDITION ASSESSMENT OF DAMAGED T-POST FRAME FOR TRUCK COVERING

    Condition assessment of T-Post for xxxxxxxx AT Panipat, Haryana Prepared By:- O.B DEVELOPERS (STRUCTURE AUDIT AGENCY) Email- strutureauditagency@gmail.com Call-+91-9717924616 www.structureauditagency.com Content S.No.                     Description of NDT Reports Page No. 1 Introduction & Scope of Work 3-5 2 Test Procedure 6-9 3 Test Results and Interpretation 10           3.4 Rebound Hammer & Ultrasonic…